Product Recalls in Massachusetts
Product recalls affecting Massachusetts — including food, drugs, consumer products, medical devices, and vehicles distributed to Massachusetts. RecallDetector monitors distribution data from the FDA, USDA, CPSC, and NHTSA to show you which recalls are relevant to your area. 1,012 recalls have been distributed to Massachusetts in the last 12 months.
Showing 37101–37120 of 52,647 recalls
Recalled Item: Atorvastatin Calcium 40 mg Recalled by Golden State Medical Supply Inc. Due...
The Issue: Failed Impurities/Degradation Specifications
Recommended Action: Stop taking this medication. Contact your pharmacy or healthcare provider.
Recalled Item: Figi's Classic Marzipan Recalled by Figi's, Inc Due to Figi's Companies is...
The Issue: Figi's Companies is recalling 8 ounce packages of "Classic Marzipan" because...
Recommended Action: Do not consume. Return to store for a refund or discard.
Recalled Item: LIFEPAK15 monitor/defibrillator with End-Tidal C02 (EtC02) feature...
The Issue: The firm became aware that when using EtC02 in the kPa or % setting and in a...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Duloxetine Delayed-Release Capsules Recalled by Apotex Scientific, Inc Due...
The Issue: Failed Dissolution Specification: Out of specification dissolution results...
Recommended Action: Stop taking this medication. Contact your pharmacy or healthcare provider.
Recalled Item: Duloxetine Delayed-Release Capsules Recalled by Apotex Scientific, Inc Due...
The Issue: Failed Dissolution Specification: Out of specification dissolution results...
Recommended Action: Stop taking this medication. Contact your pharmacy or healthcare provider.
Recalled Item: Duloxetine Delayed-Release Capsules Recalled by Apotex Scientific, Inc Due...
The Issue: Failed Dissolution Specification: Out of specification dissolution results...
Recommended Action: Stop taking this medication. Contact your pharmacy or healthcare provider.
Recalled Item: Candesartan Cilexetil Tablets Recalled by Amerisource Health Services Due to...
The Issue: Failed Impurities/Degradation Specifications; 9 month stability (manufacturer)
Recommended Action: Stop taking this medication. Contact your pharmacy or healthcare provider.
Recalled Item: Brians Cauliflower 83 oz Imported by EUROPEAN NATURAL FOOD & TRADING CO....
The Issue: Brian's Cauliflower may contain undeclared sulfites.
Recommended Action: Do not consume. Return to store for a refund or discard.
Recalled Item: Siemens Syngo Dynamics-a Picture Archiving and Communication System (PACS)...
The Issue: Siemens' conducting a recall due to a potential issue when using the...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: BD FMC7 FITC: Model 430918. FMC7 is intended for in Recalled by Becton,...
The Issue: Becton, Dickinson and Company (BD) has determined that the FMC7 FITC (ASR)...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: CyberKnife Robotic Recalled by Accuray Incorporated Due to The gun box...
The Issue: The gun box mounting bracket may fail to support the weight of the gun box...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover PREM U/M 14FR TMP SNS CSD Item Code: Recalled by Covidien LLC...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover P400 PREM U/M 16FR SLVR FLY Item Code: Recalled by Covidien...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover PPREM 18FR UL LTX FOLEY TRY CSD Item Recalled by Covidien LLC...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover P400 PREM U/M 18FR SIL COUDE CATH SECURE Recalled by Covidien...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover 400 PREM U/M 18FR SLVR FLY Item Code: Recalled by Covidien...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover P400 PREM U/M 16FR UL FOLY CSD Item Recalled by Covidien LLC...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover P400 PREM U/M 16FR SIL COUDE CATH SECURE Recalled by Covidien...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover PRECSION PRM 16FR SIL FLY Item Code: PP16SD Recalled by...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.
Recalled Item: Covidien Dover PRECISION PRM 18FR SIL COUDE CATH SECURE Item Recalled by...
The Issue: Aplicare Castile Soap towelettes included in the Foley Trays and Mid stream...
Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.