Product Recalls in Oregon

Product recalls affecting Oregon — including food, drugs, consumer products, medical devices, and vehicles distributed to Oregon. RecallDetector monitors distribution data from the FDA, USDA, CPSC, and NHTSA to show you which recalls are relevant to your area. 2,470 recalls have been distributed to Oregon in the last 12 months.

50,914 total recalls
2,470 in last 12 months

Showing 2452124540 of 28,488 recalls

Medical DeviceApril 29, 2014· Convatec Inc.

Recalled Item: Convatec Flexi Seal Control Fecal Management System Rx Only by Convatec Inc....

The Issue: Convatec Inc. is recalling Flexi-seal FMS Control Kit since it does not have...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class I — Serious Health HazardOngoing
Medical DeviceApril 29, 2014· Synthes, Inc.

Recalled Item: Synthes ProDisc-C 2.0mm Milling Bit Recalled by Synthes, Inc. Due to Certain...

The Issue: Certain lots of the ProDisc-C 2.0mm Milling Bits have an increased potential...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 28, 2014· Greatbatch Medical

Recalled Item: Coaxial Micro-Introducer Kit. Greatbatch Part Number/Bard Access Systems...

The Issue: Greatbatch identified that the documentation does not support the five-year...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 28, 2014· Baxter Healthcare Corporation

Recalled Item: Baxter MiniCap Extended Life PD Transfer Set with Twist Clamp Recalled by...

The Issue: Connection issues between the PD transfer set catheter connector and an...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 25, 2014· Hitachi Medical Systems America Inc

Recalled Item: Oasis Coil Extension Cable used with Hitachi Oasis MRI System Recalled by...

The Issue: The firm received a complaint stating the Coil Extension Cable accessory...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 25, 2014· Fresenius Medical Care Holdings, Inc.

Recalled Item: Revision K Actuator Test Boards sold as replacement parts for Recalled by...

The Issue: 2008-Series Hemodialysis Machines with Revision K Actuator Test Boards may...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 25, 2014· RAYSEARCH LABORATORIES AB

Recalled Item: RayStation software version 4.0.3.4 RayStation is a software system designed...

The Issue: This notice concerns a problem with the computation of ROI voxel volumes for...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 25, 2014· CryoLife, Inc.

Recalled Item: BG3515-5 US 5mL BioGlue Surgical Adhesive. BioGlue Surgical Adhesive...

The Issue: Serum albumin component monomer failed to meet internally established end of...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 25, 2014· Fresenius Medical Care Holdings, Inc.

Recalled Item: Fresenius 2008T Hemodialysis Machine with Revision K Actuator Test Boards...

The Issue: 2008-Series Hemodialysis Machines with Revision K Actuator Test Boards may...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS" 8" Circle Number: Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Baxter Healthcare Corp.

Recalled Item: Baxter Amia Automated PD systems are used in the treatment Recalled by...

The Issue: System error 01779 is produced when the battery cannot be charged due to...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS TM 7"x9" Reorder Recalled by Davol,...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS" 4.5" Circle Reorder Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS" 6" CircleReorder Number: Recalled...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS" 6"x8" Reorder Number: Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Composix" LIP Mesh with Echo PS" 8"x10" Reorder Number: Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿ Ventralight" ST Mesh with Echo PS" 6"x10" Reorder Number: Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Composix" LP with Echo PS" 6x8 Reorder Number: 0144680 Indicated Recalled...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Bard¿Ventralight" ST Mesh with Echo PS" 10"x13" Reorder Number: 5955113...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing
Medical DeviceApril 24, 2014· Davol, Inc., Subs. C. R. Bard, Inc.

Recalled Item: Composix" LP with Echo PS" 10x13 HUXH0294 HUXL0314 Indicated for Recalled by...

The Issue: Pouch holding sterile inflation assembly and inflation adapter may be open...

Recommended Action: Stop using. Contact the manufacturer or your healthcare provider.

Class II — Potential Health HazardOngoing